Reference: LPF
Brand: Morkom
Linear transducer LPF 75mm
Linear transducer LPF 75mm measurement length: 75mm
Reference: LPF
Brand: Morkom
Linear transducer LPF 75mm measurement length: 75mm
Reference: LPF
Brand: Morkom
Linear transducer LPF 200mm measurement length: 200mm
Reference: LPF
Brand: Morkom
Linear transducer LPF 150mm measurement length: 150mm
Reference: LTC
Brand: Atek
Linear transducer LTC 275mm measuring length: 275mm
Laser displacement sensor GFL-Z100
Security Policy
Delivery Policy
Return Policy
GFL-Z series characteristic:
Species |
Measuring center 30mm |
Measuring center 50mm |
Measuring center 100mm |
Measuring center 200mm |
Measuring center type 400mm |
|
Model |
NPN output |
GFL-Z50N |
GFL-Z100N |
GFL-Z200N |
GFL-Z400N |
|
Analog quantity output |
GFL-Z30NM |
GFL-Z50NM |
GFL-Z100NM |
GFL-Z200NM |
GFL-Z400NM |
|
RS485 communication |
GFL-Z30N-RS485 |
GFL-Z50N-RS485 |
GFL-Z100N-RS485 |
GFL-Z200N-RS485 |
GFL-Z400N-RS485 |
|
Measuring center distance |
30mm |
50mm |
100mm |
200mm |
400mm |
|
Measuring range |
±5mm |
±15mm |
±35mm |
±80mm |
±200mm |
|
Repeatability |
10μm |
30μm |
70μm |
200μm |
400μm(Measuring distance200~400mm) 800μm(Measuring distance400~600mm) |
|
Straightness |
±0.1%F.S. |
±0.2%F.S. |
±0.2%F.S.(Measuring distance200~400mm) ±0.2%F.S.(Measuring distance400~600mm) |
|||
Temperature characteristic |
0.03%F.S./℃ |
|||||
illuminant |
Red semiconductor laser Class 2 Maximum output :1mW, light beam wavelength :655nm |
|||||
Beam diameter |
About φ50μm |
About φ70μm |
Aboutφ120μm |
About φ300μm |
About φ500μm |
|
Supply voltage |
12~24V DC±10%, pulsation P-P10% |
|||||
Current consumption |
Below 40mA (24V DC supply voltage), below 60mA (12VDC supply voltage) |
|||||
Control output |
<NPN output type > NPN open collector transistor ●Maximum inow current :50mA ●Applied voltage :30V DC below (control output -0∨) ●Residual voltage: less than 1.5V (inow current 50mA) ●Leakage current: below 0.1mA |
|||||
Output action |
ON in light/ON in non-light can be switched |
|||||
Short circuit protection |
Equipped (automatic recove type) |
|||||
Analogoutput |
Voltage analog output (When alert :+5.2V) |
Output range :0 to 5V Output impedance100Ω |
- |
Output range:0~5V Output impedance: 100Ω |
- |
Output range:0~5V Output impedance: 100Ω |
Current analog output (Ale :0mA) |
Output range :4 to 20mA Load impedance :300Ω or less |
- |
Output range :4 to 20mA Load impedance :300Ω or less |
- |
Output range :4 to 20mA |
Reaction time |
1.5ms/5ms/10ms can be switched |
External input |
NPN No contact input Valid :0V to +12V DC Input impedance: about 10 kΩ |
Protective construction |
IP60 |
Degree of fouling |
2 |
Operating ambient temperature |
-10℃~+40℃(pay attention to do not condensation, icing), storage :-20℃~+60°C |
Ambient humidity |
35%~85%RH, storage :35%~85%RH |
Use ambient light |
Incandescent lamp: the illumination degree of the illuminated suace is less than 3000lx |
Service level |
Below 2000m |
Cable |
With 0.15mm 5-core composite cable 2m |
Material |
Body shell: aluminum casting front cover plate: propylene base |
weight |
Approx. 35g(without cable), Approx. 85g(with cable) |
Applicable specification |
Compliance with EMC directive |
Dimensions:
Connection scheme:
No customer reviews for the moment.
Reference: GFL-Z200
Brand: Morkom
Laser displacement sensor GFL-Z200
Reference: GFL-Z400
Brand: Morkom
Laser displacement sensor GFL-Z400
Reference: GFL-Z50
Brand: Morkom
Laser displacement sensor GFL-Z50
Reference: GFL-Z30
Brand: Morkom
Laser displacement sensor GFL-Z30